banner
COOLMECH COOLING TOWER

GST : 23BGHPB8776N1ZW

frp induced draft counter flow square cooling Tower
frp induced draft counter flow square cooling Tower

frp induced draft counter flow square cooling Tower

Price 250000.0 INR/ Unit

MOQ : 1 Unit

frp induced draft counter flow square cooling Tower Specification

  • Air Flow
  • Induced Draft, Counter Flow System
  • Application
  • Industrial Process Cooling, HVAC, Chemical & Petrochemical Plants, Power Plants, Refrigeration, Air Conditioning
  • Material
  • FRP (Fibre Reinforced Plastic) Casing & Structural Parts
  • Motor
  • TEFC Type, Squirrel Cage Induction Motor, IP55
  • Refrigerating Capacity
  • 10 TR to 1000 TR (Tons of Refrigeration) depending on model
  • Condition
  • New
  • Type
  • Induced Draft Counter Flow Square
  • Dimension (L*W*H)
  • Model Specific (e.g., 1400 x 1400 x 1800 mm and above)
  • Power Supply
  • Three Phase, 50/60 Hz
  • Voltage
  • 380-440V
  • Cooling Type
  • Water Cooled
  • Nozzle Material
  • High-Grade PVC / Polypropylene
  • Cooling Coil Material
  • Not Applicable (No coil; direct water spray over fills)
  • Water Flowing Rate
  • 100-500 m3/hr (varies as per model size and requirement)
  • Water Pump Motor
  • Available as per required flow rate and head
  • Noise Control
  • Low Noise Fans, Optional Acoustic Enclosure
  • Compressor
  • Not Applicable (Cooling Tower does not use a compressor)
  • Fan Material
  • Aluminium / FRP
  • Customization
  • Available as per Client's Design and Capacity Requirements
  • Louver Material
  • PVC / FRP for Water Splash Control
  • Drift Eliminator
  • PVC / ABS Drift Eliminators for minimum water loss
  • Inlet/Outlet Connection
  • Flanged/Grooved, as per requirement
  • Fill Media
  • PVC Honeycomb Fills / Film Fills
  • Design Standards
  • Conforms to CTI, IS & ASME Guidelines
  • Ambient Temperature Range
  • Suitable for 0C to 55C
  • Service Access
  • Access Door with SS Hinges for Inspection & Maintenance
  • Water Distribution System
  • Rotary Sprinkler or Fixed Pipe with Spray Nozzles
  • Structural Frame
  • Heavy Duty Hot Dip Galvanized Steel / SS304 optional
  • Finishing
  • UV Resistant Gelcoat Paint for Corrosion Protection
  • Maintenance
  • Easy to Maintain, Corrosion & Weather Resistant Structure
  • Packing
  • Standard Export Worthy Packing
  • Fan Type
  • Axial Flow Fan, Direct or Belt Driven as per design
  • Installation
  • Outdoor (Rooftop or Ground Mount)
  • Foundation Requirement
  • RCC/Fabricated Steel Base
 

frp induced draft counter flow square cooling Tower Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Delivery Time
  • 5-10 Days
 

About frp induced draft counter flow square cooling Tower

Short Description:

FRP Induced Draft Counter Flow Square Cooling Tower is a high-efficiency cooling system designed for industrial and HVAC applications. It is manufactured using corrosion-resistant FRP (Fiber Reinforced Plastic) material, ensuring long life and low maintenance. In this design, air is drawn upward by an induced draft fan while water flows downward in counter direction, providing maximum heat transfer efficiency. The square shape allows easy installation and space optimization.


  • Type: Induced Draft, Counter Flow

  • Shape: Square

  • Material: FRP (Fiber Reinforced Plastic) Structure

  • Capacity Range: 10 TR to 500 TR (or as per requirement)

  • Fan Type: Axial Flow Fan (Aluminum / FRP Blade)

  • Motor: TEFC / IP55 Motor

  • Fill Type: PVC Fills (High Efficiency, UV Stabilized)

  • Drift Eliminator: PVC / FRP

  • Water Distribution: PVC Sprinkler / Nozzle System

  • Structure: Heavy Duty FRP Casing

  • Application: HVAC, Chemical Plants, Power Plants, Plastic Industry, Pharma Industry



Advanced Air Distribution System

This cooling tower leverages an induced draft, counter flow configuration with a high-efficiency axial flow fan. The fan is available in both direct and belt driven options for reliability and longer operational life. With low-noise fans and optional acoustic enclosures, it maintains a quiet environment while delivering consistent airflow tailored to industrial needs.


Robust Construction for Longevity

Manufactured from premium FRP material with heavy duty hot-dip galvanized steel or optional SS304 structure, the tower is designed for outdoor installation, enduring varied weather conditions. Its UV-resistant gelcoat exterior and corrosion-proof components ensure years of seamless operation with minimal maintenance for industrial, commercial, or rooftop settings.


Optimized Water Management

Equipped with PVC honeycomb fills and drift eliminators, the tower maximizes heat exchange efficiency and minimizes water loss. The water distribution system features rotary sprinklers or fixed pipes with spray nozzles, ensuring even water coverage. Inlets and outlets are flanged or grooved as required, maintaining flexibility for easy system integration.

FAQ's of frp induced draft counter flow square cooling Tower:


Q: How does an FRP induced draft counter flow square cooling tower work?

A: This type of cooling tower utilizes an axial flow fan to draw ambient air through fill media, allowing maximum contact between air and water. Warm process water is distributed over the PVC honeycomb or film fills, cooled by the incoming airflow, and then exits at a reduced temperature for reuse in your industrial or HVAC process.

Q: What industries commonly use this type of cooling tower?

A: The cooling tower is suitable for industrial process cooling, HVAC, chemical and petrochemical plants, power generation, refrigeration, and air conditioning applications. Its robust construction and flexible design make it ideal for demanding operational environments.

Q: Where can the cooling tower be installed?

A: Designed for outdoor use, the tower can be installed on rooftops or ground mounts. Its weather resistant materials and heavy-duty structure make it compatible with a wide range of locations, even under harsh environmental conditions.

Q: What are the maintenance requirements for this cooling tower?

A: The system is engineered for easy maintenance. Access doors with stainless steel hinges allow convenient inspection and cleaning. Materials such as FRP, galvanized steel, and UV-resistant coatings minimize corrosion and wear, reducing the frequency and effort needed for maintenance.

Q: How do the drift eliminators help reduce water loss?

A: PVC or ABS drift eliminators are incorporated to trap and redirect water droplets, preventing them from escaping with the exhaust airflow. This significantly reduces water loss, making the cooling process more efficient and environmentally friendly.

Q: Can the design and capacity of the cooling tower be customized?

A: Yes, the tower can be tailored to fit specific capacity and performance requirements, offering flexibility in terms of size, water flow rates, materials, and system configuration as per client design needs.

Q: What are the benefits of using FRP material for the cooling tower?

A: FRP (Fibre Reinforced Plastic) offers excellent resistance to corrosion, chemicals, and weathering. This extends equipment lifespan, lowers maintenance costs, and ensures reliable performance in various industrial environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Cooling Tower Category

FRP Cooling Tower

FRP Cooling Tower

Price 200000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Industrial

Warranty : 1year

Color : Pastelblue

FRP Cooling Tower

FRP Cooling Tower

Price 150000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Motor : 1.5 HP, TEFC, 1440 RPM

FRP Induced Draft Round Shape Cooling Tower

FRP Induced Draft Round Shape Cooling Tower

Price 150000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Motor : IP55

Usage : Industrial

Warranty : 1 year

Color : Blue

FRP Natural Draught Cooling Tower

FRP Natural Draught Cooling Tower

Price 110000.0 INR

Minimum Order Quantity : 1

Motor : IP55

Usage : Industrial

Warranty : 1 year

Color : Blue



Back to top